We ship Anywhere in USA and Canada | Limited Time Free Shipping Code "FREESHIPPING"

Installation Instructions

Installation Instructions

Step-by-Step Guide, Safety Precautions, Maintenance Tips

Step 1
Fireplace damper installation steps

What you get in the box:
1. Cap-damper.
2. 32 ft. of SS cable.
3. Firebox Bracket pack.
4. SS cable casing.
5. Installation instructions, customer operating instructions and guarantee.
6. Sillicone.

 
Step 2
Step-2_720x600

Tools needed:
1. Wire snips
2. Screw driver
3. 1/4 mansonry bit.

Step 3
Step-3_720x600

Take the tape off the cable and drop the cable down the flue.

Step 4
Step-4_720x600
Suspe ndisse suscipit sagittis leo sit met condimentum estibulum issim Lorem ipsum dolor sit amet, consectetur cium
Step 5
Step-5_720x600 (1)

Position the firebox bracket about 2 feet above the fire floor. Position in a convenient place for the customer to use. Drill the top hole using a 3/16″
Mansory bit.

Step 6
Step-6-Left-Side-of-Firebox-Wall-300x200-1_720x600

The slot in the firebox bracket should always be towards the rear. For the left-hand side of the firebox have the tail up, for the right-hand, tail down (as shown on the rest of the installation instructions).

Step 7
04_720x600

Screw the tapcon and washer into the hole. Drill the lower hole and screw in the second tapcon.

Step 8
04_1_720x600

Thread the ball-chain handle assembly through the keyhole slot in the firebox bracket and let it hang.

 
 
Step 9
04_2_720x600

Fish the SS cable from the smoke chamber. Thread the cable through the cable casing.

Step 10
04_3_720x600

Follow it with the cable casing lock (aluminum). Slide the cable casing and lock up the smoke chamber. Place the cable casing at this point and tighten the thumbscrew to secure the lock on the cable. The lock is to keep the cable casing from sliding down the cable.

 
 
Step 11
Step-11_1_720x600

Feed the cable through the lock on the ball-chain handle, tighten and make all adjustments to the system before you
cut the cable.

 
 
Step 12
Step-12_720x600

When everything looks right, double loop the cable through cable lock and cut, leaving about 2 or 3 inches of cable extra.

 
 
Step 13
04_4_720x600

Completed firebox bracket and ball -chain handle. The installation is done! Show the customer how is works!

 
 
Step 14
Chimcare_720x600

HOME OWNER’S OPERATING
INSTRUCTIONS FOR CAP-DAMPER


(damper shown in closed position)
TO OPEN
1. pull down slightly on the spring handle ball chain from the locking slot.
2. move the spring handle toward you and up until it rests just below the firebox bracket.